Products:
 脑立体定位仪
  
ZH—Lanxing B Stereotaxic instrument
  
ZH—Lanxing D Big Animal Stereotaxic instrument
  
ZH—GSZ High Speed Skull Drill
  
ZH-lanxingC Stereotaxic instrument
 数据采集
  
ZH—HX—Z Unwound Tail Artery Blood Pressure Measure
  
Medlab—U/4C501 Biologic Signal Collection systems
 药理学仪器
  
ZH—YLS—3E Electron Pressing Pain Apparatus
  
ZH-YLS-3T Diving Tower Note Apparatus
  
ZH—LUO/B Code Displaying Program
  
ZH-YLS—8A Multifunction Inducement Cough 8i Gasp A
  
ZH—YLS—6B Intelligence Hot-board Apparatus
  
ZH—YLS—4C Rotation Fatigue Apparatus
  
ZH—YLS—7A Toe Volume Testing Apparatus
  
DW-3000 small animals breathing machine
 辅助器具
  
ZH—YLS—Q2 Big Rat Fixed Tubular Gantry
  
XYC Rat end breakage
  
ZH-YLS-Q3 Rabbit fixed
 其它设备
 
NO.A020  ZH—HX—Z Unwound Tail Artery Blood Pressure Measure
1. General introduction
Unwound tail Artery Blood Pressure Measure 8i Analysis System is special to design for watching animal blood pressure, under such condition there is no harm to animal. And the testing animal can not be anaesthetized, wounded. So it’s a convenient method. The system notes contraction pressure, diastole pressure, average pressure and heart frequency, moreover, deals with data automatically, stores and counts experiment result in some time. It’s used to chronic animal blood pressure experiment especially when making use of the system, what makes you feel free.
   
2. Function character
Note, display, determine and store contraction pressure, diastole pressure, average pressure and heart frequency. In every measuring course, average every time’s measuring value, the result will be more accurate. Conserving every animal and experiment’s accumulation data, it’s unnecessary to note these data by hand. Handling data automatically, storing and counting some time’s experiment result, the preserved data can be input into Excel statistical table directly, then we statistics analyze the data and form the table what makes writing paper turn easy. The preserved charts are bmp documents, so you can use any chart compiling software to compile for paper. For original data being preserved, they can be reappeared and measured again. Not only computer but user by hand measures the data.. The user decides to hold the data or not by himself.
3.Technical index
Medlab collection system
ZH—100 pulse Transfer Energy Apparatus
ZH Blood Pressure Transfer Energy Apparatus
Blood pressure table
Channel amount: 4 channels
Software operation terrace:
Windows 2000/xp
ME/98, standardized Windows interface Driver program.
Have special Medlab-USB facility driver program
The data shares together with Excel
Sampling velocity is 1.6μs and maximum passing velocity is 800k bytes/second.
Input data through USB structure
①Response frequency:≥1500HZ
②No source
③Outputting electric cable has two fuses
④External size: 16.5×6
 
①Measuring, scope
②Full measuring scope outputting >30mv
③No linear degree<0.1%FS
④Delay<0.5%FS
⑤operating voltage: 5—8v D.C.
⑥Zero line flow<0.05%h(FS)
⑦Insulation resistance>500 mΩ/100v
⑧Pressure limit is measuring scope’s 4 times
⑨Outputting resistance is from 1kΩ to 2kΩ
⑩Operating temperature: -20℃-+80℃
①Two graduations: kPa, mmHg
②Minimum graduation: 0.5kpa/kpa mmHg/2mmHg
③Error:±0.5KPa  ±0.75mmhg
④Zero line≤1KPa or ±0.5mmhg
 
 
POWERED BY HTSOFT  MEDIA
  安徽省淮北市濉溪经济开发区玉兰大道17号 
电话:0561-6061044   邮编:235100 
传真:0561-6062307  